...
Start the CTI License Manager from the Windows Start Menu
Click the Accept button to close the Privacy Notice.
Click the Status Button
Verify that Sidescan acquisition or one of the Sidescan-Combo acquisition modules are licensed as shown below:
For USB Dongle Key users:
...
Right-Click a Survey Line to open the Context Menu
Select Generate Lines Parallel to the Selected Line…
In the Cloning Line dialog, fill in the desired settings for the new lines
Click OK
These new lines will also be listed in the Survey Lines branch of the Project Explorer
...
Click on the Data Acquisition Views drop-down
Left-Click and drag the Waterfall Display 1 with the mouse
While holding the mouse button down, hover the mouse over one of the docking icons that appear as you pan over the screen
Release the mouse to drop the Waterfall display into place as shown below:
Repeat this for each of the Waterfall Display 1, the System Information panel, the Sensor Status Panel and the Left-Right Steering indicator. We placed the widgets like this:
...
Open your SonarWiz project.
Click the Data Acquisition > Sonar icon to open the Select Sonar Interface dialog
In the Sidescan section, look for the PulSARServer and select it.
Click the Start/Configure button
At this point the PulSAR interface should launch. Verify that the PulSAR interface is listed in the Current Servers: Sidescan section.
Verify that the SonarWiz indicator is green on the PulSAR Server interface. This indicates that the server has a connection to SonarWiz.
Note |
---|
The PulSAR server interface should remain running throughout your survey. It is OK to minimize the window, but do not close it or the connection between SonarWiz and the interface deck box (IDU) will be lost. |
...
Click the Advanced… button
Enter the Sound Speed in Water for your survey area (m/s)
Click OK.
Configure Server Acquisition and Transmitter Settings
...
Right-click in the real-time waterfall display you want to adjust
Select Adjust SSS Gains… from the Context Menu
Adjust the gain settings as desired
Click OK to apply the settings
Info |
---|
Remember, when you change the gain settings you are changing the intensity values of the data. This will affect how colors are mapped to your data. If your data gets too dark or too light after gain adjustments, open up the Color Window and re-adjust the palette mapping or use one of the automatic color modes. |
...
Click the Stop Recording icon to stop all logging.
Open the Sonar Interface window by click Data Acquisition > Sonar.
In the Current Servers section, click Disconnect from any servers that are currently listed.
In the PulSAR Interface server, click Quit button.
Close SonarWiz.
...
Page Properties | ||
---|---|---|
| ||
|